Current Position:Home>>Cell Products>>Cell Apoptosis Assay>>Mitochondrial Apoptosis Assay>> Mitochondrial Membrane Potential Assay Kit (with JC-1)
Cat.No.:E-CK-A301
Welcome to order from local distributors.
Add to cart Bulk request
For research use only. Order now, ship in 3 days
The decrease of mitochondrial membrane potential is a marker event in the early stage of apoptosis. It occurs before the appearance of nuclear apoptotic features (chromatin condensation and DNA fragmentation). Once the mitochondrial membrane potential collapses, apoptosis is irreversible. JC-1 is an ideal fluorescent probe widely used to detect mitochondrial membrane potential ∆Ψm. In normal cells, the mitochondrial membrane potential is high, JC-1 aggregates in the mitochondrial matrix to form a polymer, which can produce red fluorescence. In the early stage of apoptosis, the mitochondrial membrane potential decreases, JC-1 can’t accumulate in the mitochondrial matrix. When JC-1 is a monomer, it can produce green fluorescence. The decrease of cell membrane potential can be detected by the transition of JC-1 from red fluorescence to green fluorescence, and the transition of JC-1 fluorescence color can be used as an early detection indicator of cell apoptosis. The relative ratio of red and green fluorescence is commonly used to measure the ratio of mitochondrial depolarization. The maximum excitation wavelength of JC-1 monomer is 514 nm and the maximum emission wavelength is 529 nm; the maximum excitation wavelength of JC-1 polymer is 585 nm and the maximum emission wavelength is 590 nm.
Application | JC-1 |
Detection method | Fluorometric Method |
Sample type | Cell samples |
Assay time | 40min |
Detection instrument | Flow Cytometer, Fluorescence Microscope, Confocal Microscopes |
Dye Type | JC-1 |
Ex/Em (nm) | 514/529, 585/590 |
Channel set | FITC, PE |
Filter set | FITC, TRITC |
Other reagents required | Ultrapure water |
Storage | 2~8°C/-20°C, shading light. Refer to the Manual. |
Shipping | Ice bag |
Expiration date | 12 months |
E-CK-A320 | One-step TUNEL In Situ Apoptosis Kit (Green, FITC) |
E-CK-A211 | Annexin V-FITC/PI Apoptosis Kit |
E-CK-A362 | Enhanced Cell Counting Kit 8 (WST-8/CCK8) |
PMID: 35659626 |
DOI: 10.1111/cns.14085 |
|
PMID: 34994554 |
R***********dSubmitted [ Jun 24 2024 ]
Asked: Dear, I have a question concerning the following product : Mitochondrial Membrane Potential Assay Kit (with JC-1) Cat.No.:E-CK-A301. Should CCCP be incubated at 37°C or at room temperature ? Thank you in advance for your help. Cordially, Rose Guignard
Reply
adminSubmitted [ Jun 24 2024 ]
Answered: Dear customer: Regarding your question about Mitochondrial Membrane Potential Assay Kit (with JC-1) Cat.No.:E-CK-A301, CCCP should be incubated at 37°C. If you need any further information, please contact customer02@elabscience.com, Thank you.